1 .\"
2 .\" swapcache - Cache clean filesystem data & meta-data on SSD-based swap
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .Dd February 7, 2010
13 .Dt SWAPCACHE 8
14 .Os
15 .Sh NAME
16 .Nm swapcache
17 .Nd a mechanism to use fast swap to cache filesystem data and meta-data
18 .Sh SYNOPSIS
19 .Cd sysctl vm.swapcache.accrate=100000
20 .Cd sysctl vm.swapcache.maxfilesize=0
21 .Cd sysctl vm.swapcache.maxburst=2000000000
22 .Cd sysctl vm.swapcache.curburst=4000000000
23 .Cd sysctl vm.swapcache.minburst=10000000
24 .Cd sysctl vm.swapcache.read_enable=0
25 .Cd sysctl vm.swapcache.meta_enable=0
26 .Cd sysctl vm.swapcache.data_enable=0
27 .Cd sysctl vm.swapcache.use_chflags=1
28 .Cd sysctl vm.swapcache.maxlaunder=256
29 .Cd sysctl vm.swapcache.hysteresis=(vm.stats.vm.v_inactive_target/2)
30 .Sh DESCRIPTION
31 .Nm
32 is a system capability which allows a solid state disk (SSD) in a swap
33 space configuration to be used to cache clean filesystem data and meta-data
34 in addition to its normal function of backing anonymous memory.
35 .Pp
36 Sysctls are used to manage operational parameters and can be adjusted at
37 any time.
38 Typically a large initial burst is desired after system boot,
39 controlled by the initial
40 .Va vm.swapcache.curburst
41 parameter.
42 This parameter is reduced as data is written to swap by the swapcache
43 and increased at a rate specified by
44 .Va vm.swapcache.accrate .
45 Once this parameter reaches zero write activity ceases until it has
46 recovered sufficiently for write activity to resume.
47 .Pp
48 .Va vm.swapcache.meta_enable
49 enables the writing of filesystem meta-data to the swapcache.
50 Filesystem
51 metadata is any data which the filesystem accesses via the disk device
52 using buffercache.
53 Meta-data is cached globally regardless of file or directory flags.
54 .Pp
55 .Va vm.swapcache.data_enable
56 enables the writing of clean filesystem file-data to the swapcache.
57 Filesystem filedata is any data which the filesystem accesses via a
58 regular file.
59 In technical terms, when the buffer cache is used to access
60 a regular file through its vnode.
61 Please do not blindly turn on this option, see the
62 .Sx PERFORMANCE TUNING
63 section for more information.
64 .Pp
65 .Va vm.swapcache.use_chflags
66 enables the use of the
67 .Va cache
68 and
69 .Va noscache
70 .Xr chflags 1
71 flags to control which files will be data-cached.
72 If this sysctl is disabled and
73 .Va data_enable
74 is enabled, the system will ignore file flags and attempt to
75 swapcache all regular files.
76 .Pp
77 .Va vm.swapcache.read_enable
78 enables reading from the swapcache and should be set to 1 for normal
79 operation.
80 .Pp
81 .Va vm.swapcache.maxfilesize
82 controls which files are to be cached based on their size.
83 If set to non-zero only files smaller than the specified size
84 will be cached.
85 Larger files will not be cached.
86 .Pp
87 .Va vm.swapcache.maxlaunder
88 controls the maximum number of clean VM pages which will be added to
89 the swap cache and written out to swap on each poll.
90 Swapcache polls ten times a second.
91 .Pp
92 .Va vm.swapcache.hysteresis
93 controls how many pages swapcache waits to be added to the inactive page
94 queue before continuing its scan.
95 Once it decides to scan it continues subject to the above limitations
96 until it reaches the end of the inactive page queue.
97 This parameter is designed to make swapcache generate more bulky bursts
98 to swap which helps SSDs reduce write amplification effects.
99 .Sh PERFORMANCE TUNING
100 Best operation is achieved when the active data set fits within the
101 swapcache.
102 .Pp
103 .Bl -tag -width 4n -compact
104 .It Va vm.swapcache.accrate
105 This specifies the burst accumulation rate in bytes per second and
106 ultimately controls the write bandwidth to swap averaged over a long
107 period of time.
108 This parameter must be carefully chosen to manage the write endurance of
109 the SSD in order to avoid wearing it out too quickly.
110 Even though SSDs have limited write endurance, there is massive
111 cost/performance benefit to using one in a swapcache configuration.
112 .Pp
113 Let's use the old Intel X25V 40GB MLC SATA SSD as an example.
114 This device has approximately a
115 40TB (40 terabyte) write endurance, but see later
116 notes on this, it is more a minimum value.
117 Limiting the long term average bandwidth to 100KB/sec leads to no more
118 than ~9GB/day writing which calculates approximately to a 12 year endurance.
119 Endurance scales linearly with size.
120 The 80GB version of this SSD
121 will have a write endurance of approximately 80TB.
122 .Pp
123 MLC SSDs have a 1000-10000x write endurance, while the lower density
124 higher-cost SLC SSDs have a 10000-100000x write endurance, approximately.
125 MLC SSDs can be used for the swapcache (and swap) as long as the system
126 manager is cognizant of its limitations.
127 However, over the years tests have shown the SLC SSDs do not really live
128 up to their hype and are no more reliable than MLC SSDs.  Instead of
129 worrying about SLC vs MLC, just use MLC (or TLC or whateve), leave
130 more space unpartitioned which the SSD can utilize to improve durability,
131 and be cognizant of the SSDs rate of wear.
132 .Pp
133 .It Va vm.swapcache.meta_enable
134 Turning on just
135 .Va meta_enable
136 causes only filesystem meta-data to be cached and will result
137 in very fast directory operations even over millions of inodes
138 and even in the face of other invasive operations being run
139 by other processes.
140 .Pp
141 For
142 .Nm HAMMER
143 filesystems meta-data includes the B-Tree, directory entries,
144 and data related to tiny files.
145 Approximately 6 GB of swapcache is needed
146 for every 14 million or so inodes cached, effectively giving one the
147 ability to cache all the meta-data in a multi-terabyte filesystem using
148 a fairly small SSD.
149 .Pp
150 .It Va vm.swapcache.data_enable
151 Turning on
152 .Va data_enable
153 (with or without other features) allows bulk file data to be cached.
154 This feature is very useful for web server operation when the
155 operational data set fits in swap.
156 However, care must be taken to avoid thrashing the swapcache.
157 In almost all cases you will want to leave chflags mode enabled
158 and use 'chflags cache' on governing directories to control which
159 directory subtrees file data should be cached for.
160 .Pp
161 .Dx
162 uses generously large kern.maxvnodes values,
163 typically in excess of 400K vnodes, but large numbers
164 of small files can still cause problems for swapcache.
165 When operating on a filesystem containing a large number of
166 small files, vnode recycling by the kernel will cause related
167 swapcache data to be lost and also cause the swapcache to
168 potentially thrash.
169 Cache thrashing due to vnode recyclement can occur whether chflags
170 mode is used or not.
171 .Pp
172 To solve the thrashing problem you can turn on HAMMER's
173 double buffering feature via
174 .Va vfs.hammer.double_buffer .
175 This causes HAMMER to cache file data via its block device.
176 HAMMER cannot avoid also caching file data via individual vnodes
177 but will try to expire the second copy more quickly (hence
178 why it is called double buffer mode), but the key point here is
179 that
180 .Nm
181 will only cache the data blocks via the block device when
182 double_buffer mode is used and since the block device is associated
183 with the mount, vnode recycling will not mess with it.
184 This allows the data for any number (potentially millions) of files to
185 be swapcached.
186 You still should use chflags mode to control the size of the dataset
187 being cached to remain under 75% of configured swap space.
188 .Pp
189 Data caching is definitely more wasteful of the SSD's write durability
190 than meta-data caching.
191 If not carefully managed the swapcache may exhaust its burst and smack
192 against the long term average bandwidth limit, causing the SSD to wear
193 out at the maximum rate you programmed.
194 Data caching is far less wasteful and more efficient
195 if you provide a sufficiently large SSD.
196 .Pp
197 When caching large data sets you may want to use a medium-sized SSD
198 with good write performance instead of a small SSD to accommodate
199 the higher burst write rate data caching incurs and to reduce
200 interference between reading and writing.
201 Write durability also tends to scale with larger SSDs, but keep in mind
202 that newer flash technologies use smaller feature sizes on-chip
203 which reduce the write durability of the chips, so pay careful attention
204 to the type of flash employed by the SSD when making durability
205 assumptions.
206 For example, an Intel X25-V only has 40MB/s in write performance
207 and burst writing by swapcache will seriously interfere with
208 concurrent read operation on the SSD.
209 The 80GB X25-M on the otherhand has double the write performance.
210 Higher-capacity and larger form-factor SSDs tend to have better
211 write-performance.
212 But the Intel 310 series SSDs use flash chips with a smaller feature
213 size so an 80G 310 series SSD will wind up with a durability relative
214 close to the older 40G X25-V.
215 .Pp
216 When data caching is turned on you can fine-tune what gets swapcached
217 by also turning on swapcache's chflags mode and using
218 .Xr chflags 1
219 with the
220 .Va cache
221 flag to enable data caching on a directory-tree (recursive) basis.
222 This flag is tracked by the namecache and does not need to be
223 recursively set in the directory tree.
224 Simply setting the flag in a top level directory or mount point
225 is usually sufficient.
226 However, the flag does not track across mount points.
227 A typical setup is something like this:
228 .Pp
229 .Dl chflags cache /etc /sbin /bin /usr /home
230 .Dl chflags noscache /usr/obj
231 .Pp
232 It is possible to tell
233 .Nm
234 to ignore the cache flag by leaving
235 .Va vm.swapcache.use_chflags
236 set to zero.
237 In many situations it is convenient to simply not use chflags mode, but
238 if you have numerous mixed SSDs and HDDs you may want to use this flag
239 to enable swapcache on the HDDs and disable it on the SSDs even if
240 you do not care about fine-grained control.
241 .Nm chflag Ns 'ing .
242 .Pp
243 Filesystems such as NFS which do not support flags generally
244 have a
245 .Va cache
246 mount option which enables swapcache operation on the mount.
247 .Pp
248 .It Va vm.swapcache.maxfilesize
249 This may be used to reduce cache thrashing when a focus on a small
250 potentially fragmented filespace is desired, leaving the
251 larger (more linearly accessed) files alone.
252 .Pp
253 .It Va vm.swapcache.minburst
254 This controls hysteresis and prevents nickel-and-dime write bursting.
255 Once
256 .Va curburst
257 drops to zero, writing to the swapcache ceases until it has recovered past
258 .Va minburst .
259 The idea here is to avoid creating a heavily fragmented swapcache where
260 reading data from a file must alternate between the cache and the primary
261 filesystem.
262 Doing so does not save disk seeks on the primary filesystem
263 so we want to avoid doing small bursts.
264 This parameter allows us to do larger bursts.
265 The larger bursts also tend to improve SSD performance as the SSD itself
266 can do a better job write-combining and erasing blocks.
267 .Pp
268 .It Va vm_swapcache.maxswappct
269 This controls the maximum amount of swapspace
270 .Nm
271 may use, in percentage terms.
272 The default is 75%, leaving the remaining 25% of swap available for normal
273 paging operations.
274 .El
275 .Pp
276 It is important to ensure that your swap partition is nicely aligned.
277 The standard
278 .Dx
279 .Xr disklabel 8
280 program guarantees high alignment (~1MB) automatically.
281 Swap-on HDDs benefit because HDDs tend to use a larger physical sector size
282 than 512 bytes, and proper alignment for SSDs will reduce write amplification
283 and write-combining inefficiencies.
284 .Pp
285 Finally, interleaved swap (multiple SSDs) may be used to increase
286 swap and swapcache performance even further.
287 A single SATA-II SSD is typically capable of reading 120-220MB/sec.
288 Configuring two SSDs for your swap will
289 improve aggregate swapcache read performance by 1.5x to 1.8x.
290 In tests with two Intel 40GB SSDs 300MB/sec was easily achieved.
291 With two SATA-III SSDs it is possible to achieve 600MB/sec or better
292 and well over 400MB/sec random-read performance (versus the ~3MB/sec
293 random read performance a hard drive gives you).
294 Faster SATA interfaces or newer NVMe technologies have significantly
295 more read bandwidth (3GB/sec+ for NVMe), but may still lag on the
296 write bandwidth.
297 With newer technologies, one swap device is usually plenty.
298 .Pp
299 .Dx
300 defaults to a maximum of 512G of configured swap.
301 Keep in mind that each 1GB of actually configured swap requires
302 approximately 1MB of wired ram to manage.
303 .Pp
304 In addition there will be periods of time where the system is in
305 steady state and not writing to the swapcache.
306 During these periods
307 .Va curburst
308 will inch back up but will not exceed
309 .Va maxburst .
310 Thus the
311 .Va maxburst
312 value controls how large a repeated burst can be.
313 Remember that
314 .Va curburst
315 dynamically tracks burst and will go up and down depending.
316 .Pp
317 A second bursting parameter called
318 .Va vm.swapcache.minburst
319 controls bursting when the maximum write bandwidth has been reached.
320 When
321 .Va minburst
322 reaches zero write activity ceases and
323 .Va curburst
324 is allowed to recover up to
325 .Va minburst
326 before write activity resumes.
327 The recommended range for the
328 .Va minburst
329 parameter is 1MB to 50MB.
330 This parameter has a relationship to
331 how fragmented the swapcache gets when not in a steady state.
332 Large bursts reduce fragmentation and reduce incidences of
333 excessive seeking on the hard drive.
334 If set too low the
335 swapcache will become fragmented within a single regular file
336 and the constant back-and-forth between the swapcache and the
337 hard drive will result in excessive seeking on the hard drive.
338 .Sh SWAPCACHE SIZE & MANAGEMENT
339 The swapcache feature will use up to 75% of configured swap space
340 by default.
341 The remaining 25% is reserved for normal paging operations.
342 The system operator should configure at least 4 times the SWAP space
343 versus main memory and no less than 8GB of swap space.
344 A typical 128GB SSD might use 64GB for boot + base and 56GB for
345 swap, with 8GB left unpartitioned.  The system might then have a large
346 additional hard drive for bulk data.
347 Even with many packages installed, 64GB is comfortable for
348 boot + base.
349 .Pp
350 When configuring a SSD that will be used for swap or swapcache
351 it is a good idea to leave around 10% unpartitioned to improve
352 the SSDs durability.
353 .Pp
354 You do not need to use swapcache if you have no hard drives in the
355 system, though in fact swapcache can help if you use NFS heavily
356 as a client.
357 .Pp
358 The
359 .Va vm_swapcache.maxswappct
360 sysctl may be used to change the default.
361 You may have to change this default if you also use
362 .Xr tmpfs 5 ,
363 .Xr vn 4 ,
364 or if you have not allocated enough swap for reasonable normal paging
365 activity to occur (in which case you probably shouldn't be using
366 .Nm
367 anyway).
368 .Pp
369 If swapcache reaches the 75% limit it will begin tearing down swap
370 in linear bursts by iterating through available VM objects, until
371 swap space use drops to 70%.
372 The tear-down is limited by the rate at
373 which new data is written and this rate in turn is often limited by
374 .Va vm.swapcache.accrate ,
375 resulting in an orderly replacement of cached data and meta-data.
376 The limit is typically only reached when doing full data+meta-data
377 caching with no file size limitations and serving primarily large
378 files, or bumping
379 .Va kern.maxvnodes
380 up to very high values.
381 .Sh NORMAL SWAP PAGING ACTIVITY WITH SSD SWAP
382 This is not a function of
383 .Nm
384 per se but instead a normal function of the system.
385 Most systems have
386 sufficient memory that they do not need to page memory to swap.
387 These types of systems are the ones best suited for MLC SSD
388 configured swap running with a
389 .Nm
390 configuration.
391 Systems which modestly page to swap, in the range of a few hundred
392 megabytes a day worth of writing, are also well suited for MLC SSD
393 configured swap.
394 Desktops usually fall into this category even if they
395 page out a bit more because swap activity is governed by the actions of
396 a single person.
397 .Pp
398 Systems which page anonymous memory heavily when
399 .Nm
400 would otherwise be turned off are not usually well suited for MLC SSD
401 configured swap.
402 Heavy paging activity is not governed by
403 .Nm
404 bandwidth control parameters and can lead to excessive uncontrolled
405 writing to the SSD, causing premature wearout.
406 This isn't to say that
407 .Nm
408 would be ineffective, just that the aggregate write bandwidth required
409 to support the system might be too large to be cost-effective for a SSD.
410 .Pp
411 With this caveat in mind, SSD based paging on systems with insufficient
412 RAM can be extremely effective in extending the useful life of the system.
413 For example, a system with a measly 192MB of RAM and SSD swap can run
414 a -j 8 parallel build world in a little less than twice the time it
415 would take if the system had 2GB of RAM, whereas it would take 5x to 10x
416 as long with normal HDD based swap.
417 .Sh USING SWAPCACHE WITH NORMAL HARD DRIVES
418 Although
419 .Nm
420 is designed to work with SSD-based storage it can also be used with
421 HD-based storage as an aid for offloading the primary storage system.
422 Here we need to make a distinction between using RAID for fanning out
423 storage versus using RAID for redundancy.  There are numerous situations
424 where RAID-based redundancy does not make sense.
425 .Pp
426 A good example would be in an environment where the servers themselves
427 are redundant and can suffer a total failure without effecting
428 ongoing operations.  When the primary storage requirements easily fit onto
429 a single large-capacity drive it doesn't make a whole lot of sense to
430 use RAID if your only desire is to improve performance.  If you had a farm
431 of, say, 20 servers supporting the same facility adding RAID to each one
432 would not accomplish anything other than to bloat your deployment and
433 maintenance costs.
434 .Pp
435 In these sorts of situations it may be desirable and convenient to have
436 the primary filesystem for each machine on a single large drive and then
437 use the
438 .Nm
439 facility to offload the drive and make the machine more effective without
440 actually distributing the filesystem itself across multiple drives.
441 For the purposes of offloading while a SSD would be the most effective
442 from a performance standpoint, a second medium sized HD with its much lower
443 cost and higher capacity might actually be more cost effective.
444 .Sh EXPLANATION OF STATIC VS DYNAMIC WEARING LEVELING, AND WRITE-COMBINING
445 Modern SSDs keep track of space that has never been written to.
446 This would also include space freed up via TRIM, but simply not
447 touching a bit of storage in a factory fresh SSD works just as well.
448 Once you touch (write to) the storage all bets are off, even if
449 you reformat/repartition later.  It takes sending the SSD a
450 whole-device TRIM command or special format command to take it back
451 to its factory-fresh condition (sans wear already present).
452 .Pp
453 SSDs have wear leveling algorithms which are responsible for trying
454 to even out the erase/write cycles across all flash cells in the
455 storage.  The better a job the SSD can do the longer the SSD will
456 remain usable.
457 .Pp
458 The more unused storage there is from the SSDs point of view the
459 easier a time the SSD has running its wear leveling algorithms.
460 Basically the wear leveling algorithm in a modern SSD (say Intel or OCZ)
461 uses a combination of static and dynamic leveling.  Static is the
462 best, allowing the SSD to reuse flash cells that have not been
463 erased very much by moving static (unchanging) data out of them and
464 into other cells that have more wear.  Dynamic wear leveling involves
465 writing data to available flash cells and then marking the cells containing
466 the previous copy of the data as being free/reusable.  Dynamic wear leveling
467 is the worst kind but the easiest to implement.  Modern SSDs use a combination
468 of both algorithms plus also do write-combining.
469 .Pp
470 USB sticks often use only dynamic wear leveling and have short life spans
471 because of that.
472 .Pp
473 In anycase, any unused space in the SSD effectively makes the dynamic
474 wear leveling the SSD does more efficient by giving the SSD more 'unused'
475 space above and beyond the physical space it reserves beyond its stated
476 storage capacity to cycle data through, so the SSD lasts longer in theory.
477 .Pp
478 Write-combining is a feature whereby the SSD is able to reduced write
479 amplification effects by combining OS writes of smaller, discrete,
480 non-contiguous logical sectors into a single contiguous 128KB physical
481 flash block.
482 .Pp
483 On the flip side write-combining also results in more complex lookup tables
484 which can become fragmented over time and reduce the SSDs read performance.
485 Fragmentation can also occur when write-combined blocks are rewritten
486 piecemeal.
487 Modern SSDs can regain the lost performance by de-combining previously
488 write-combined areas as part of their static wear leveling algorithm, but
489 at the cost of extra write/erase cycles which slightly increase write
490 amplification effects.
491 Operating systems can also help maintain the SSDs performance by utilizing
492 larger blocks.
493 Write-combining results in a net-reduction
494 of write-amplification effects but due to having to de-combine later and
495 other fragmentary effects it isn't 100%.
496 From testing with Intel devices write-amplification can be well controlled
497 in the 2x-4x range with the OS doing 16K writes, versus a worst-case
498 8x write-amplification with 16K blocks, 32x with 4K blocks, and a truly
499 horrid worst-case with 512 byte blocks.
500 .Pp
501 The
502 .Dx
503 .Nm
504 feature utilizes 64K-128K writes and is specifically designed to minimize
505 write amplification and write-combining stresses.
506 In terms of placing an actual filesystem on the SSD, the
507 .Dx
508 .Xr hammer 8
509 filesystem utilizes 16K blocks and is well behaved as long as you limit
510 reblocking operations.
511 For UFS you should create the filesystem with at least a 4K fragment
512 size, versus the default 2K.
513 Modern Windows filesystems use 4K clusters but it is unclear how SSD-friendly
514 NTFS is.
515 .Sh EXPLANATION OF FLASH CHIP FEATURE SIZE VS ERASE/REWRITE CYCLE DURABILITY
516 Manufacturers continue to produce flash chips with smaller feature sizes.
517 Smaller flash cells means reduced erase/rewrite cycle durability which in
518 turn reduces the durability of the SSD.
519 .Pp
520 The older 34nm flash typically had a 10,000 cell durability while the newer
521 25nm flash is closer to 1000.  The newer flash uses larger ECCs and more
522 sensitive voltage comparators on-chip to increase the durability closer to
523 3000 cycles.  Generally speaking you should assume a durability of around
524 1/3 for the same storage capacity using the new chips versus the older
525 chips.  If you can squeeze out a 400TB durability from an older 40GB X25-V
526 using 34nm technology then you should assume around a 400TB durability from
527 a newer 120GB 310 series SSD using 25nm technology.
528 .Sh WARNINGS
529 I am going to repeat and expand a bit on SSD wear.
530 Wear on SSDs is a function of the write durability of the cells,
531 whether the SSD implements static or dynamic wear leveling (or both),
532 write amplification effects when the OS does not issue write-aligned 128KB
533 ops or when the SSD is unable to write-combine adjacent logical sectors,
534 or if the SSD has a poor write-combining algorithm for non-adjacent sectors.
535 In addition some additional erase/rewrite activity occurs from cleanup
536 operations the SSD performs as part of its static wear leveling algorithms
537 and its write-decombining algorithms (necessary to maintain performance over
538 time).  MLC flash uses 128KB physical write/erase blocks while SLC flash
539 typically uses 64KB physical write/erase blocks.
540 .Pp
541 The algorithms the SSD implements in its firmware are probably the most
542 important part of the device and a major differentiator between e.g. SATA
543 and USB-based SSDs.  SATA form factor drives will universally be far superior
544 to USB storage sticks.
545 SSDs can also have wildly different wearout rates and wildly different
546 performance curves over time.
547 For example the performance of a SSD which does not implement
548 write-decombining can seriously degrade over time as its lookup
549 tables become severely fragmented.
550 For the purposes of this manual page we are primarily using Intel and OCZ
551 drives when describing performance and wear issues.
552 .Pp
553 .Nm
554 parameters should be carefully chosen to avoid early wearout.
555 For example, the Intel X25V 40GB SSD has a minimum write durability
556 of 40TB and an actual durability that can be quite a bit higher.
557 Generally speaking, you want to select parameters that will give you
558 at least 10 years of service life.
559 The most important parameter to control this is
560 .Va vm.swapcache.accrate .
561 .Nm
562 uses a very conservative 100KB/sec default but even a small X25V
563 can probably handle 300KB/sec of continuous writing and still last 10 years.
564 .Pp
565 Depending on the wear leveling algorithm the drive uses, durability
566 and performance can sometimes be improved by configuring less
567 space (in a manufacturer-fresh drive) than the drive's probed capacity.
568 For example, by only using 32GB of a 40GB SSD.
569 SSDs typically implement 10% more storage than advertised and
570 use this storage to improve wear leveling.
571 As cells begin to fail
572 this overallotment slowly becomes part of the primary storage
573 until it has been exhausted.
574 After that the SSD has basically failed.
575 Keep in mind that if you use a larger portion of the SSD's advertised
576 storage the SSD will not know if/when you decide to use less unless
577 appropriate TRIM commands are sent (if supported), or a low level
578 factory erase is issued.
579 .Pp
580 .Nm smartctl
581 (from
582 .Xr dports 7 Ap s
583 .Pa sysutils/smartmontools )
584 may be used to retrieve the wear indicator from the drive.
585 One usually runs something like
586 .Ql smartctl -d sat -a /dev/daXX
587 (for AHCI/SILI/SCSI), or
588 .Ql smartctl -a /dev/adXX
589 for NATA.
590 Some SSDs
591 (particularly the Intels) will brick the SATA port when smart operations
592 are done while the drive is busy with normal activity, so the tool should
593 only be run when the SSD is idle.
594 .Pp
595 ID 232 (0xe8) in the SMART data dump indicates available reserved
596 space and ID 233 (0xe9) is the wear-out meter.
597 Reserved space
598 typically starts at 100 and decrements to 10, after which the SSD
599 is considered to operate in a degraded mode.
600 The wear-out meter typically starts at 99 and decrements to 0,
601 after which the SSD has failed.
602 .Pp
603 .Nm
604 tends to use large 64KB writes and tends to cluster multiple writes
605 linearly.
606 The SSD is able to take significant advantage of this
607 and write amplification effects are greatly reduced.
608 If we take a 40GB Intel X25V as an example the vendor specifies a write
609 durability of approximately 40TB, but
610 .Nm
611 should be able to squeeze out upwards of 200TB due the fairly optimal
612 write clustering it does.
613 The theoretical limit for the Intel X25V is 400TB (10,000 erase cycles
614 per MLC cell, 40GB drive, with 34nm technology), but the firmware doesn't
615 do perfect static wear leveling so the actual durability is less.
616 In tests over several hundred days we have validated a write endurance
617 greater than 200TB on the 40G Intel X25V using
618 .Nm .
619 .Pp
620 In contrast, filesystems directly stored on a SSD could have
621 fairly severe write amplification effects and will have durabilities
622 ranging closer to the vendor-specified limit.
623 .Pp
624 Tests have shown that power cycling (with proper shutdown) and read
625 operations do not adversely effect a SSD.  Writing within the wearout
626 constraints provided by the vendor also does not make a powered SSD any
627 less reliable over time.  Time itself seems to be a factor as the SSD
628 encounters defects and weak cells in the flash chips.  Writes to a SSD
629 will effect cold durability (a typical flash chip has 10 years of cold
630 data retention when fresh and less than 1 year of cold data retention near
631 the end of its wear life).  Keeping a SSD cool improves its data retention.
632 .Pp
633 Beware the standard comparison between SLC, MLC, and TLC-based flash
634 in terms of wearout and durability.  Over the years, tests have shown
635 that SLC is not actually any more reliable than MLC, despite having a
636 significantly larger theoretical durability.  Cell and chip failures seem
637 to trump theoretical wear limitations in terms of device reliability.
638 With that in mind, we do not recommend using SLC for anything anymore.
639 Instead we recommend that the flash simply be over-provisioned to provide
640 the needed durability.
641 This is already done in numerous NVMe solutions for the vendor to be able
642 to provide certain minimum wear guarantees.
643 Durability scales with the amount of flash storage (but the fab process
644 typically scales the opposite... smaller feature sizes for flash cells
645 greatly reduce their durability).
646 When wear calculations are in years, these differences become huge, but
647 often the quantity of storage needed trumps the wear life so we expect most
648 people will be using MLC.
649 .Pp
650 Beware the huge difference between larger (e.g. 2.5") form-factor SSDs
651 and smaller SSDs such as USB sticks are very small M.2 storage.  Smaller
652 form-factor devices have fewer flash chips and, much lower write bandwidths,
653 less ram for caching and write-combining, and usb sticks in particular will
654 usually have unsophisticated wear-leveling algorithms compared to a 2.5"
655 SSD.  It is generally not a good idea to make a USB stick your primary
656 storage.  Long-form-factor NGFF/M.2 devices will be better, and 2.5"
657 form factor devices even better.  The read-bandwidth for a SATA SSD caps
658 out more quickly than the read-bandwidth for a NVMe SSD, but the larger
659 form factor of a 2.5" SATA SSD will often have superior write performance
660 to a NGFF NVMe device.  There are 2.5" NVMe devices as well, requiring a
661 special connector or PCIe adapter, which give you the best of both worlds.
662 .Sh SEE ALSO
663 .Xr chflags 1 ,
664 .Xr fstab 5 ,
665 .Xr disklabel64 8 ,
666 .Xr hammer 8 ,
667 .Xr swapon 8
668 .Sh HISTORY
669 .Nm
670 first appeared in
671 .Dx 2.5 .
672 .Sh AUTHORS
673 .An Matthew Dillon