Initial import from FreeBSD RELENG_4:
[dragonfly.git] / sbin / startslip / startslip.1
1 .\" Copyright (c) 1990, 1991, 1993
2 .\"     The Regents of the University of California.  All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\" 3. All advertising materials mentioning features or use of this software
13 .\"    must display the following acknowledgement:
14 .\"     This product includes software developed by the University of
15 .\"     California, Berkeley and its contributors.
16 .\" 4. Neither the name of the University nor the names of its contributors
17 .\"    may be used to endorse or promote products derived from this software
18 .\"    without specific prior written permission.
19 .\"
20 .\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
21 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
22 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
23 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
24 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
25 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
26 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
27 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
28 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
29 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
30 .\" SUCH DAMAGE.
31 .\"
32 .\"     @(#)startslip.1 8.1 (Berkeley) 6/5/93
33 .\" $FreeBSD: src/sbin/startslip/startslip.1,v 1.16.2.5 2002/06/20 23:09:11 charnier Exp $
34 .\"
35 .Dd June 5, 1993
36 .Dt STARTSLIP 1
37 .Os
38 .Sh NAME
39 .Nm startslip
40 .Nd dial up and login to a slip server
41 .Sh SYNOPSIS
42 .Nm
43 .Op Fl d
44 .Op Fl b Ar speed
45 .Oo
46 .Fl s Ar string1
47 .Op Fl s Ar string2 Op Ar ...\&
48 .Oc
49 .Op Fl h
50 .Op Fl l
51 .Op Fl L
52 .Op Fl A Ar annexname
53 .Op Fl U Ar upscript
54 .Op Fl D Ar downscript
55 .Op Fl t Ar script_timeout
56 .Op Fl W Ar maxtries
57 .Op Fl w Ar retry_pause
58 .Op Fl K Ar keepalive
59 .Op Fl O Ar outfill
60 .Op Fl S Ar unit
61 .Ar device user password
62 .Sh DESCRIPTION
63 The
64 .Nm
65 utility opens the specified
66 .Ar device .
67 Once carrier is asserted (if modem control is enabled)
68 .Nm
69 attempts to login as the specified
70 .Ar user
71 with the given
72 .Ar password .
73 Standard login: & Password: scheme assumed unless Annex option
74 specified (see
75 .Fl A ) .
76 If successful, it puts the device into the slip line discipline,
77 calls
78 .Ar upscript
79 and goes to wait mode.
80 If carrier drops (modem control enabled) or a
81 .Dv SIGHUP
82 is sent to
83 .Nm ,
84 it closes the device, calls
85 .Ar downscript
86 and attempts to repeat the dialup and login sequence.
87 If a
88 .Dv SIGTERM
89 is send to
90 .Nm ,
91 it closes the device, calls
92 .Ar downscript
93 and exits.
94 When
95 .Nm
96 called twice on the same device, previous copy killed by a
97 .Dv SIGTERM
98 before any operation.
99 .Pp
100 The following options are available:
101 .Bl -tag -width indent
102 .It Fl d
103 Print out debugging information.
104 .It Fl b Ar speed
105 Determine the baud rate used for
106 .Ar device ,
107 default value is 9600.
108 .It Fl t Ar script_timeout
109 Set login script timeout in seconds, default value is 90.
110 .It Fl w Ar retry_pause
111 Set connecting retry pause in seconds (increased from one retry to another),
112 default value is 60.
113 .It Fl W Ar maxtries
114 Set maximum number of connection retries for one session,
115 default value is 6.
116 Value 0 means infinite count.
117 .It Fl s Ar stringN
118 The optional
119 .Ar stringN
120 is written to
121 .Ar device .
122 Return character is added automatically.
123 For a dialup modem,
124 the string is used to specify a dial sequence.
125 No string written by default.
126 You can specify several
127 .Fl s Ar stringN
128 arguments to use with each try, f.e. several host phone numbers.
129 .It Fl A Ar annexname
130 The
131 .Nm
132 utility assumes it is connecting to a Xylogics Annex box and engages in an
133 appropriate dialog using the
134 .Ar user
135 and
136 .Ar password
137 arguments.
138 The
139 .Ar annexname
140 argument is a string that is used to match against the Annex prompt
141 to determine when a connection has been established.
142 .It Fl h
143 Use hardware (CTS/RTS) flow control for
144 .Ar device .
145 Default value is no flow control.
146 .It Fl l
147 Disable modem control (waiting for carrier and carrier drop sense) for
148 .Ar device .
149 Modem control is enabled by default.
150 .It Fl U Ar upscript
151 Specify a script to run when a SLIP interface becomes connected.  This may
152 contain
153 .Xr ifconfig 8 ,
154 .Xr route 8 ,
155 and other appropriate commands.  The arguments that
156 are passed to the script are "slX up".
157 Default value is
158 .Pa /sbin/ifconfig .
159 Dial sequence number (see
160 .Fl s )
161 passed via
162 .Ev LINE
163 environment variable.
164 .It Fl D Ar downscript
165 Specify a script to run when a SLIP connection goes away.  The arguments that
166 are passed to the script are "slX down". Default value is
167 .Pa /sbin/ifconfig .
168 Dial sequence number (see
169 .Fl s )
170 passed via
171 .Ev LINE
172 environment variable.
173 .It Fl K Ar keepalive
174 Set SLIP "keep alive" timeout in seconds.
175 If FRAME_END not received during this
176 time period, a reconnect will occur.
177 Active "out fill" timeout expected from other
178 side.
179 Default value is no timeout.
180 .It Fl O Ar outfill
181 Set SLIP "out fill" timeout in seconds.
182 It causes at least one FRAME_END
183 to be sent during this timeout.
184 Needed for "keep alive" timeout on other side.
185 Default value is no timeout.
186 .It Fl S Ar unit
187 Set SLIP unit number directly.
188 Use with caution, no check for two
189 interfaces with same number made.
190 Default is dynamic assignment.
191 .It Fl L
192 Use uucp-style device locking.
193 You need it unless you start
194 .Nm
195 from external program which already does uucp locking.
196 Default case is no uucp locking to satisfy such programs.
197 .El
198 .Sh FILES
199 .Bl -tag -width /var/run/startslip.<device>.pid -compact
200 .It Pa /var/run/startslip.<device>.pid
201 pid stored here
202 .It Pa /usr/share/examples/startslip/*
203 .El
204 .Sh SEE ALSO
205 .Xr uustat 1 ,
206 .Xr slattach 8 ,
207 .Xr sliplogin 8
208 .Sh HISTORY
209 The
210 .Nm
211 appeared in
212 .Bx 4.4 .