9b8b8b216b4761ad08c39a20ed16cba12d7b9786
[dragonfly.git] / usr.sbin / mlxcontrol / mlxcontrol.8
1 .\"
2 .\" Copyright (c) 2000 Michael Smith
3 .\" All rights reserved.
4 .\"
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
7 .\" are met:
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. The name of the author may not be used to endorse or promote products
11 .\"    derived from this software without specific prior written permission
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
14 .\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
15 .\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
16 .\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
17 .\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
18 .\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
19 .\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
20 .\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
21 .\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
22 .\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
23 .\"
24 .\" $FreeBSD: src/usr.sbin/mlxcontrol/mlxcontrol.8,v 1.10 2010/10/08 12:40:16 uqs Exp $
25 .\"
26 .Dd November 20, 2010
27 .Dt MLXCONTROL 8
28 .Os
29 .Sh NAME
30 .Nm mlxcontrol
31 .Nd Mylex DAC-family RAID management utility
32 .Sh SYNOPSIS
33 .Nm
34 .Aq command
35 .Op args
36 .Nm
37 status
38 .Op Fl qv
39 .Op Ar drive
40 .Nm
41 rescan
42 .Ar controller
43 .Op Ar controller ...
44 .Nm
45 detach
46 .Ar drive
47 .Op Ar drive ...
48 .Nm
49 detach
50 .Fl a
51 .Nm
52 check
53 .Ar drive
54 .Nm
55 config
56 .Ar controller
57 .Nm
58 help
59 .Ar command
60 .Sh DESCRIPTION
61 The
62 .Nm
63 utility provides status monitoring and management functions
64 for devices attached
65 to the
66 .Xr mlx 4
67 driver.
68 .Pp
69 Controller names are of the form "mlxN"
70 where N is the unit number of the controller.
71 Drive names are of the form "mlxdN"
72 where N is the unit number of the drive.
73 Do not specify the path to a device node.
74 .Bl -tag -width rebuild
75 .It status
76 Print the status of controllers and system drives.
77 If one or more drives are specified,
78 only print information about these drives,
79 otherwise print information
80 about all controllers and drives in the system.
81 With the
82 .Fl v
83 flag, display much more verbose information.
84 With the
85 .Fl q
86 flag, do not print any output.
87 This command returns
88 0 if all drives tested are online,
89 1 if one or more drives are critical and
90 2 if one or more are offline.
91 .It rescan
92 Rescan one or more controllers for non-attached system drives
93 (e.g.\& drives that have been
94 detached or created subsequent to driver initialisation).
95 If the
96 .Fl a
97 flag is supplied, rescan all controllers in the system.
98 .It detach
99 Detach one or more system drives.
100 Drives must be unmounted
101 and not opened by any other utility for this command to succeed.
102 If the
103 .Fl a
104 flag is supplied, detach all system drives from the nominated controller.
105 .It check
106 Initiate a consistency check and repair pass on a redundant system drive
107 (e.g.\& RAID1 or RAID5).
108 The controller will scan the system drive and repair any inconsistencies.
109 This command returns immediately;
110 use the
111 .Ar status
112 command to monitor the progress of the check.
113 .It rebuild
114 Requires two arguments,
115 .Ar controller
116 and
117 .Ar physdrive
118 as specified in the
119 output of the
120 .Ar status
121 command.
122 All system drives using space on the physical drive
123 .Ar physdrive
124 are rebuilt, reconstructing all data on the drive.
125 Note that each controller can only perform one rebuild at a time.
126 This command returns immediately; use the
127 .Ar status
128 command to monitor the progress of the rebuild.
129 .It config
130 Print the current configuration from the nominated controller.
131 This command will be updated
132 to allow addition/deletion of system drives from a configuration
133 in a future release.
134 .It help
135 Print usage information for
136 .Ar command .
137 .El
138 .Sh AUTHORS
139 The
140 .Nm
141 utility was written by
142 .An Michael Smith
143 .Aq msmith@FreeBSD.org .
144 .Sh BUGS
145 The
146 .Ar config
147 command does not yet support modifying system drive configuration.
148 .Pp
149 Error log extraction is not yet supported.