RocketRAID 18xx Driver for FreeBSD Copyright (C) 2007-2008 HighPoint Technologies, Inc. All rights reserved. $FreeBSD: src/sys/dev/hptmv/readme.txt,v 1.4 2009/04/07 16:38:25 delphij Exp $ ############################################################################# Revision History: v1.16 2008-2-29 Fix 7.0 compile error. v1.15 2007-8-6 Override kernel driver(built-in) to support over 2T RAID array. v1.14 2006-3-21 Fix 48-bit LBA compatibility for Seagate drives. Fix 16 bytes CDB support. v1.13 2006-2-13 Fix fail LED/beeper control. Add 16 bytes CDB support. v1.12 2005-6-10 Fix over 4G memory support on amd64. Fix disk flush problem. v1.1 2004-9-23 Fix activity LED problem. Cleanup diagnostic code. v1.01 2004-5-24 First source code release ############################################################################# 1. Overview --------------------- This package contains FreeBSD driver source code for HighPoint RocketRAID 18xx SATA controller. NO WARRANTY THE DRIVER SOURCE CODE HIGHPOINT PROVIDED IS FREE OF CHARGE, AND THERE IS NO WARRANTY FOR THE PROGRAM. THERE ARE NO RESTRICTIONS ON THE USE OF THIS FREE SOURCE CODE. HIGHPOINT DOES NOT PROVIDE ANY TECHNICAL SUPPORT IF THE CODE HAS BEEN CHANGED FROM ORIGINAL SOURCE CODE. LIMITATION OF LIABILITY IN NO EVENT WILL HIGHPOINT BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, HIGHPOINT SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, OR RECOVERING SUCH HARDWARE, OR DATA. 2. Rebuild the kernel with RR18xx support -------------------------------------------- 1) Install kernel source package and building tools. 2) Extract the driver files under the kernel source tree: # cd /usr/src/sys/ # tar xvzf /your/path/to/rr18xx-opensource-v1.12-bsd.tgz 3) Update the kernel configuration file to include the HighPoint source. Assume the configure file is GENERIC, and new kernel configure file is MYKERNEL: # cd i386/conf (or amd64/conf for AMD64) # cp GENERIC MYKERNEL 4) Edit MYKERNEL, and add the following line under "RAID controllers interfaced to the SCSI subsystem": device hptmv #HighPoint RocketRAID 18xx 5) For i386 system, edit /usr/src/sys/conf/files.i386 and append the lines shown below: hptmvraid.o optional hptmv \ dependency "$S/dev/hptmv/i386-elf.raid.o.uu" \ compile-with "uudecode < $S/dev/hptmv/i386-elf.raid.o.uu" \ no-implicit-rule dev/hptmv/gui_lib.c optional hptmv dev/hptmv/hptproc.c optional hptmv dev/hptmv/ioctl.c optional hptmv dev/hptmv/entry.c optional hptmv dev/hptmv/mv.c optional hptmv For amd64 system, edit /usr/src/sys/conf/files.amd64 and append the lines shown below: hptmvraid.o optional hptmv \ dependency "$S/dev/hptmv/amd64-elf.raid.o.uu" \ compile-with "uudecode < $S/dev/hptmv/amd64-elf.raid.o.uu" \ no-implicit-rule dev/hptmv/gui_lib.c optional hptmv dev/hptmv/hptproc.c optional hptmv dev/hptmv/ioctl.c optional hptmv dev/hptmv/entry.c optional hptmv dev/hptmv/mv.c optional hptmv Note FreeBSD 5.3/5.4/6.x/7.x i386 already have a built-in RR18xx driver, you should replace the old configuration lines with the lines listed above. 6) Rebuild and install the kernel: a) for FreeBSD 5.x/6.x/7.x i386: # cd /usr/src/sys/i386/conf/ # /usr/sbin/config MYKERNEL # cd ../compile/MYKERNEL/ # make depend # make # make install b) for FreeBSD 5.x/6.x/7.x amd64: # cd /usr/src/sys/amd64/conf/ # /usr/sbin/config MYKERNEL # cd ../compile/MYKERNEL/ # make depend # make # make install c) for FreeBSD 4.x: # cd /usr/src/sys/i386/conf/ # /usr/sbin/config MYKERNEL # cd ../../compile/MYKERNEL/ # make depend # make # make install If the driver was previously configured as an auto-loaded module by /boot/defaults/loader.conf, please remove the entry hptmv_load="YES" from loader.conf to prevent the driver from being loaded twice. 7) Reboot from the new kernel. 3. Build/Load the driver as a kernel module ------------------------------------------------ 1) Install kernel source package and building tools. 2) Extract the driver files under the kernel source tree: # cd /usr/src/sys/ # tar xvzf /your/path/to/rr18xx-opensource-v1.12-bsd.tgz 4) Build the driver module: # cd modules/hptmv # make 5) Copy the driver module to the kernel module directory For FreeBSD 4.x: # cp hptmv.ko /modules/ For FreeBSD 5.x/6.x/7.x: # cp hptmv.ko /boot/kernel/ 6) Reboot and load the driver under loader prompt. e.g: BTX loader 1.00 BTX version is 1.01 Console: internal video/keyboard BIOS driver A: is disk0 BIOS driver C: is disk2 BIOS 636kB/74512kB available memory FreeBSD/i386 bootstrap loader, Revision 0.8 (mailto:jkh@narf.osd.bsdi.com, Sat Apr 21 08:46:19 GMT 2001) Loading /boot/defaults/loader.conf /kernel text=0x24f1db data=0x3007ec+0x2062c - Hit [Enter] to boot immediagely, or any other key for command prompt. Booting [kernel] in 9 secondsĄ­ <-- press SPACE key here Type '?' for a list of commands, 'help' for more detailed help. ok load hptmv /modules/hptmv.ko text=0xf571 data=0x2c8+0x254 ok boot For FreeBSD 5.x/6.x/7.x, you can select 6 on the boot menu to get a loader prompt. 7) You can add a below line into /boot/defaults/loader.conf to load the driver automatically: hptmv_load="YES" Please refer to the installation guide in HighPoint FreeBSD driver release package for more information. ############################################################################# Technical support and service If you have questions about installing or using your HighPoint product, check the user's guide or readme file first, and you will find answers to most of your questions here. If you need further assistance, please contact us. We offer the following support and information services: 1) The HighPoint Web Site provides information on software upgrades, answers to common questions, and other topics. The Web Site is available from Internet 24 hours a day, 7 days a week, at http://www.highpoint-tech.com. 2) For technical support, send e-mail to support@highpoint-tech.com NOTE: Before you send an e-mail, please visit our Web Site (http://www.highpoint-tech.com) to check if there is a new or updated device driver for your system.