Merge tag 'pci-v6.4-fixes-1' of git://git.kernel.org/pub/scm/linux/kernel/git/pci/pci
[linux.git] / drivers / net / Kconfig
1 # SPDX-License-Identifier: GPL-2.0-only
2 #
3 # Network device configuration
4 #
5
6 menuconfig NETDEVICES
7         default y if UML
8         depends on NET
9         bool "Network device support"
10         help
11           You can say N here if you don't intend to connect your Linux box to
12           any other computer at all.
13
14           You'll have to say Y if your computer contains a network card that
15           you want to use under Linux. If you are going to run SLIP or PPP over
16           telephone line or null modem cable you need say Y here. Connecting
17           two machines with parallel ports using PLIP needs this, as well as
18           AX.25/KISS for sending Internet traffic over amateur radio links.
19
20           See also "The Linux Network Administrator's Guide" by Olaf Kirch and
21           Terry Dawson. Available at <http://www.tldp.org/guides.html>.
22
23           If unsure, say Y.
24
25 # All the following symbols are dependent on NETDEVICES - do not repeat
26 # that for each of the symbols.
27 if NETDEVICES
28
29 config MII
30         tristate
31
32 config NET_CORE
33         default y
34         bool "Network core driver support"
35         help
36           You can say N here if you do not intend to use any of the
37           networking core drivers (i.e. VLAN, bridging, bonding, etc.)
38
39 if NET_CORE
40
41 config BONDING
42         tristate "Bonding driver support"
43         depends on INET
44         depends on IPV6 || IPV6=n
45         depends on TLS || TLS_DEVICE=n
46         help
47           Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
48           Channels together. This is called 'Etherchannel' by Cisco,
49           'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.
50
51           The driver supports multiple bonding modes to allow for both high
52           performance and high availability operation.
53
54           Refer to <file:Documentation/networking/bonding.rst> for more
55           information.
56
57           To compile this driver as a module, choose M here: the module
58           will be called bonding.
59
60 config DUMMY
61         tristate "Dummy net driver support"
62         help
63           This is essentially a bit-bucket device (i.e. traffic you send to
64           this device is consigned into oblivion) with a configurable IP
65           address. It is most commonly used in order to make your currently
66           inactive SLIP address seem like a real address for local programs.
67           If you use SLIP or PPP, you might want to say Y here. It won't
68           enlarge your kernel. What a deal. Read about it in the Network
69           Administrator's Guide, available from
70           <http://www.tldp.org/docs.html#guide>.
71
72           To compile this driver as a module, choose M here: the module
73           will be called dummy.
74
75 config WIREGUARD
76         tristate "WireGuard secure network tunnel"
77         depends on NET && INET
78         depends on IPV6 || !IPV6
79         depends on !KMSAN # KMSAN doesn't support the crypto configs below
80         select NET_UDP_TUNNEL
81         select DST_CACHE
82         select CRYPTO
83         select CRYPTO_LIB_CURVE25519
84         select CRYPTO_LIB_CHACHA20POLY1305
85         select CRYPTO_CHACHA20_X86_64 if X86 && 64BIT
86         select CRYPTO_POLY1305_X86_64 if X86 && 64BIT
87         select CRYPTO_BLAKE2S_X86 if X86 && 64BIT
88         select CRYPTO_CURVE25519_X86 if X86 && 64BIT
89         select CRYPTO_CHACHA20_NEON if ARM || (ARM64 && KERNEL_MODE_NEON)
90         select CRYPTO_POLY1305_NEON if ARM64 && KERNEL_MODE_NEON
91         select CRYPTO_POLY1305_ARM if ARM
92         select CRYPTO_BLAKE2S_ARM if ARM
93         select CRYPTO_CURVE25519_NEON if ARM && KERNEL_MODE_NEON
94         select CRYPTO_CHACHA_MIPS if CPU_MIPS32_R2
95         select CRYPTO_POLY1305_MIPS if MIPS
96         select CRYPTO_CHACHA_S390 if S390
97         help
98           WireGuard is a secure, fast, and easy to use replacement for IPSec
99           that uses modern cryptography and clever networking tricks. It's
100           designed to be fairly general purpose and abstract enough to fit most
101           use cases, while at the same time remaining extremely simple to
102           configure. See www.wireguard.com for more info.
103
104           It's safe to say Y or M here, as the driver is very lightweight and
105           is only in use when an administrator chooses to add an interface.
106
107 config WIREGUARD_DEBUG
108         bool "Debugging checks and verbose messages"
109         depends on WIREGUARD
110         help
111           This will write log messages for handshake and other events
112           that occur for a WireGuard interface. It will also perform some
113           extra validation checks and unit tests at various points. This is
114           only useful for debugging.
115
116           Say N here unless you know what you're doing.
117
118 config EQUALIZER
119         tristate "EQL (serial line load balancing) support"
120         help
121           If you have two serial connections to some other computer (this
122           usually requires two modems and two telephone lines) and you use
123           SLIP (the protocol for sending Internet traffic over telephone
124           lines) or PPP (a better SLIP) on them, you can make them behave like
125           one double speed connection using this driver.  Naturally, this has
126           to be supported at the other end as well, either with a similar EQL
127           Linux driver or with a Livingston Portmaster 2e.
128
129           Say Y if you want this and read
130           <file:Documentation/networking/eql.rst>.  You may also want to read
131           section 6.2 of the NET-3-HOWTO, available from
132           <http://www.tldp.org/docs.html#howto>.
133
134           To compile this driver as a module, choose M here: the module
135           will be called eql.  If unsure, say N.
136
137 config NET_FC
138         bool "Fibre Channel driver support"
139         depends on SCSI && PCI
140         help
141           Fibre Channel is a high speed serial protocol mainly used to connect
142           large storage devices to the computer; it is compatible with and
143           intended to replace SCSI.
144
145           If you intend to use Fibre Channel, you need to have a Fibre channel
146           adaptor card in your computer; say Y here and to the driver for your
147           adaptor below. You also should have said Y to "SCSI support" and
148           "SCSI generic support".
149
150 config IFB
151         tristate "Intermediate Functional Block support"
152         depends on NET_ACT_MIRRED || NFT_FWD_NETDEV
153         select NET_REDIRECT
154         help
155           This is an intermediate driver that allows sharing of
156           resources.
157           To compile this driver as a module, choose M here: the module
158           will be called ifb.  If you want to use more than one ifb
159           device at a time, you need to compile this driver as a module.
160           Instead of 'ifb', the devices will then be called 'ifb0',
161           'ifb1' etc.
162           Look at the iproute2 documentation directory for usage etc
163
164 source "drivers/net/team/Kconfig"
165
166 config MACVLAN
167         tristate "MAC-VLAN support"
168         help
169           This allows one to create virtual interfaces that map packets to
170           or from specific MAC addresses to a particular interface.
171
172           Macvlan devices can be added using the "ip" command from the
173           iproute2 package starting with the iproute2-2.6.23 release:
174
175           "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"
176
177           To compile this driver as a module, choose M here: the module
178           will be called macvlan.
179
180 config MACVTAP
181         tristate "MAC-VLAN based tap driver"
182         depends on MACVLAN
183         depends on INET
184         select TAP
185         help
186           This adds a specialized tap character device driver that is based
187           on the MAC-VLAN network interface, called macvtap. A macvtap device
188           can be added in the same way as a macvlan device, using 'type
189           macvtap', and then be accessed through the tap user space interface.
190
191           To compile this driver as a module, choose M here: the module
192           will be called macvtap.
193
194 config IPVLAN_L3S
195         depends on NETFILTER
196         depends on IPVLAN
197         def_bool y
198         select NET_L3_MASTER_DEV
199
200 config IPVLAN
201         tristate "IP-VLAN support"
202         depends on INET
203         depends on IPV6 || !IPV6
204         help
205           This allows one to create virtual devices off of a main interface
206           and packets will be delivered based on the dest L3 (IPv6/IPv4 addr)
207           on packets. All interfaces (including the main interface) share L2
208           making it transparent to the connected L2 switch.
209
210           Ipvlan devices can be added using the "ip" command from the
211           iproute2 package starting with the iproute2-3.19 release:
212
213           "ip link add link <main-dev> [ NAME ] type ipvlan"
214
215           To compile this driver as a module, choose M here: the module
216           will be called ipvlan.
217
218 config IPVTAP
219         tristate "IP-VLAN based tap driver"
220         depends on IPVLAN
221         depends on INET
222         select TAP
223         help
224           This adds a specialized tap character device driver that is based
225           on the IP-VLAN network interface, called ipvtap. An ipvtap device
226           can be added in the same way as a ipvlan device, using 'type
227           ipvtap', and then be accessed through the tap user space interface.
228
229           To compile this driver as a module, choose M here: the module
230           will be called ipvtap.
231
232 config VXLAN
233         tristate "Virtual eXtensible Local Area Network (VXLAN)"
234         depends on INET
235         select NET_UDP_TUNNEL
236         select GRO_CELLS
237         help
238           This allows one to create vxlan virtual interfaces that provide
239           Layer 2 Networks over Layer 3 Networks. VXLAN is often used
240           to tunnel virtual network infrastructure in virtualized environments.
241           For more information see:
242             http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02
243
244           To compile this driver as a module, choose M here: the module
245           will be called vxlan.
246
247 config GENEVE
248         tristate "Generic Network Virtualization Encapsulation"
249         depends on INET
250         depends on IPV6 || !IPV6
251         select NET_UDP_TUNNEL
252         select GRO_CELLS
253         help
254           This allows one to create geneve virtual interfaces that provide
255           Layer 2 Networks over Layer 3 Networks. GENEVE is often used
256           to tunnel virtual network infrastructure in virtualized environments.
257           For more information see:
258             http://tools.ietf.org/html/draft-gross-geneve-02
259
260           To compile this driver as a module, choose M here: the module
261           will be called geneve.
262
263 config BAREUDP
264         tristate "Bare UDP Encapsulation"
265         depends on INET
266         depends on IPV6 || !IPV6
267         select NET_UDP_TUNNEL
268         select GRO_CELLS
269         help
270           This adds a bare UDP tunnel module for tunnelling different
271           kinds of traffic like MPLS, IP, etc. inside a UDP tunnel.
272
273           To compile this driver as a module, choose M here: the module
274           will be called bareudp.
275
276 config GTP
277         tristate "GPRS Tunneling Protocol datapath (GTP-U)"
278         depends on INET
279         select NET_UDP_TUNNEL
280         help
281           This allows one to create gtp virtual interfaces that provide
282           the GPRS Tunneling Protocol datapath (GTP-U). This tunneling protocol
283           is used to prevent subscribers from accessing mobile carrier core
284           network infrastructure. This driver requires a userspace software that
285           implements the signaling protocol (GTP-C) to update its PDP context
286           base, such as OpenGGSN <http://git.osmocom.org/openggsn/). This
287           tunneling protocol is implemented according to the GSM TS 09.60 and
288           3GPP TS 29.060 standards.
289
290           To compile this drivers as a module, choose M here: the module
291           will be called gtp.
292
293 config AMT
294         tristate "Automatic Multicast Tunneling (AMT)"
295         depends on INET && IP_MULTICAST
296         depends on IPV6 || !IPV6
297         select NET_UDP_TUNNEL
298         help
299           This allows one to create AMT(Automatic Multicast Tunneling)
300           virtual interfaces that provide multicast tunneling.
301           There are two roles, Gateway, and Relay.
302           Gateway Encapsulates IGMP/MLD traffic from listeners to the Relay.
303           Gateway Decapsulates multicast traffic from the Relay to Listeners.
304           Relay Encapsulates multicast traffic from Sources to Gateway.
305           Relay Decapsulates IGMP/MLD traffic from Gateway.
306
307           To compile this drivers as a module, choose M here: the module
308           will be called amt.
309
310 config MACSEC
311         tristate "IEEE 802.1AE MAC-level encryption (MACsec)"
312         select CRYPTO
313         select CRYPTO_AES
314         select CRYPTO_GCM
315         select GRO_CELLS
316         help
317            MACsec is an encryption standard for Ethernet.
318
319 config NETCONSOLE
320         tristate "Network console logging support"
321         help
322           If you want to log kernel messages over the network, enable this.
323           See <file:Documentation/networking/netconsole.rst> for details.
324
325 config NETCONSOLE_DYNAMIC
326         bool "Dynamic reconfiguration of logging targets"
327         depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
328                         !(NETCONSOLE=y && CONFIGFS_FS=m)
329         help
330           This option enables the ability to dynamically reconfigure target
331           parameters (interface, IP addresses, port numbers, MAC addresses)
332           at runtime through a userspace interface exported using configfs.
333           See <file:Documentation/networking/netconsole.rst> for details.
334
335 config NETPOLL
336         def_bool NETCONSOLE
337
338 config NET_POLL_CONTROLLER
339         def_bool NETPOLL
340
341 config NTB_NETDEV
342         tristate "Virtual Ethernet over NTB Transport"
343         depends on NTB_TRANSPORT
344
345 config RIONET
346         tristate "RapidIO Ethernet over messaging driver support"
347         depends on RAPIDIO
348
349 config RIONET_TX_SIZE
350         int "Number of outbound queue entries"
351         depends on RIONET
352         default "128"
353
354 config RIONET_RX_SIZE
355         int "Number of inbound queue entries"
356         depends on RIONET
357         default "128"
358
359 config TUN
360         tristate "Universal TUN/TAP device driver support"
361         depends on INET
362         select CRC32
363         help
364           TUN/TAP provides packet reception and transmission for user space
365           programs.  It can be viewed as a simple Point-to-Point or Ethernet
366           device, which instead of receiving packets from a physical media,
367           receives them from user space program and instead of sending packets
368           via physical media writes them to the user space program.
369
370           When a program opens /dev/net/tun, driver creates and registers
371           corresponding net device tunX or tapX.  After a program closed above
372           devices, driver will automatically delete tunXX or tapXX device and
373           all routes corresponding to it.
374
375           Please read <file:Documentation/networking/tuntap.rst> for more
376           information.
377
378           To compile this driver as a module, choose M here: the module
379           will be called tun.
380
381           If you don't know what to use this for, you don't need it.
382
383 config TAP
384         tristate
385         help
386           This option is selected by any driver implementing tap user space
387           interface for a virtual interface to re-use core tap functionality.
388
389 config TUN_VNET_CROSS_LE
390         bool "Support for cross-endian vnet headers on little-endian kernels"
391         default n
392         help
393           This option allows TUN/TAP and MACVTAP device drivers in a
394           little-endian kernel to parse vnet headers that come from a
395           big-endian legacy virtio device.
396
397           Userspace programs can control the feature using the TUNSETVNETBE
398           and TUNGETVNETBE ioctls.
399
400           Unless you have a little-endian system hosting a big-endian virtual
401           machine with a legacy virtio NIC, you should say N.
402
403 config VETH
404         tristate "Virtual ethernet pair device"
405         select PAGE_POOL
406         select PAGE_POOL_STATS
407         help
408           This device is a local ethernet tunnel. Devices are created in pairs.
409           When one end receives the packet it appears on its pair and vice
410           versa.
411
412 config VIRTIO_NET
413         tristate "Virtio network driver"
414         depends on VIRTIO
415         select NET_FAILOVER
416         help
417           This is the virtual network driver for virtio.  It can be used with
418           QEMU based VMMs (like KVM or Xen).  Say Y or M.
419
420 config NLMON
421         tristate "Virtual netlink monitoring device"
422         help
423           This option enables a monitoring net device for netlink skbs. The
424           purpose of this is to analyze netlink messages with packet sockets.
425           Thus applications like tcpdump will be able to see local netlink
426           messages if they tap into the netlink device, record pcaps for further
427           diagnostics, etc. This is mostly intended for developers or support
428           to debug netlink issues. If unsure, say N.
429
430 config NET_VRF
431         tristate "Virtual Routing and Forwarding (Lite)"
432         depends on IP_MULTIPLE_TABLES
433         depends on NET_L3_MASTER_DEV
434         depends on IPV6 || IPV6=n
435         depends on IPV6_MULTIPLE_TABLES || IPV6=n
436         help
437           This option enables the support for mapping interfaces into VRF's. The
438           support enables VRF devices.
439
440 config VSOCKMON
441         tristate "Virtual vsock monitoring device"
442         depends on VHOST_VSOCK
443         help
444           This option enables a monitoring net device for vsock sockets. It is
445           mostly intended for developers or support to debug vsock issues. If
446           unsure, say N.
447
448 config MHI_NET
449         tristate "MHI network driver"
450         depends on MHI_BUS
451         help
452           This is the network driver for MHI bus.  It can be used with
453           QCOM based WWAN modems for IP or QMAP/rmnet protocol (like SDX55).
454           Say Y or M.
455
456 endif # NET_CORE
457
458 config SUNGEM_PHY
459         tristate
460
461 source "drivers/net/arcnet/Kconfig"
462
463 source "drivers/atm/Kconfig"
464
465 source "drivers/net/caif/Kconfig"
466
467 source "drivers/net/dsa/Kconfig"
468
469 source "drivers/net/ethernet/Kconfig"
470
471 source "drivers/net/fddi/Kconfig"
472
473 source "drivers/net/hippi/Kconfig"
474
475 source "drivers/net/ipa/Kconfig"
476
477 config NET_SB1000
478         tristate "General Instruments Surfboard 1000"
479         depends on PNP
480         help
481           This is a driver for the General Instrument (also known as
482           NextLevel) SURFboard 1000 internal
483           cable modem. This is an ISA card which is used by a number of cable
484           TV companies to provide cable modem access. It's a one-way
485           downstream-only cable modem, meaning that your upstream net link is
486           provided by your regular phone modem.
487
488           At present this driver only compiles as a module, so say M here if
489           you have this card. The module will be called sb1000. Then read
490           <file:Documentation/networking/device_drivers/cable/sb1000.rst> for
491           information on how to use this module, as it needs special ppp
492           scripts for establishing a connection. Further documentation
493           and the necessary scripts can be found at:
494
495           <http://www.jacksonville.net/~fventuri/>
496           <http://home.adelphia.net/~siglercm/sb1000.html>
497           <http://linuxpower.cx/~cable/>
498
499           If you don't have this card, of course say N.
500
501 source "drivers/net/phy/Kconfig"
502
503 source "drivers/net/pse-pd/Kconfig"
504
505 source "drivers/net/can/Kconfig"
506
507 source "drivers/net/mctp/Kconfig"
508
509 source "drivers/net/mdio/Kconfig"
510
511 source "drivers/net/pcs/Kconfig"
512
513 source "drivers/net/plip/Kconfig"
514
515 source "drivers/net/ppp/Kconfig"
516
517 source "drivers/net/slip/Kconfig"
518
519 source "drivers/s390/net/Kconfig"
520
521 source "drivers/net/usb/Kconfig"
522
523 source "drivers/net/wireless/Kconfig"
524
525 source "drivers/net/wan/Kconfig"
526
527 source "drivers/net/ieee802154/Kconfig"
528
529 source "drivers/net/wwan/Kconfig"
530
531 config XEN_NETDEV_FRONTEND
532         tristate "Xen network device frontend driver"
533         depends on XEN
534         select XEN_XENBUS_FRONTEND
535         select PAGE_POOL
536         default y
537         help
538           This driver provides support for Xen paravirtual network
539           devices exported by a Xen network driver domain (often
540           domain 0).
541
542           The corresponding Linux backend driver is enabled by the
543           CONFIG_XEN_NETDEV_BACKEND option.
544
545           If you are compiling a kernel for use as Xen guest, you
546           should say Y here. To compile this driver as a module, chose
547           M here: the module will be called xen-netfront.
548
549 config XEN_NETDEV_BACKEND
550         tristate "Xen backend network device"
551         depends on XEN_BACKEND
552         help
553           This driver allows the kernel to act as a Xen network driver
554           domain which exports paravirtual network devices to other
555           Xen domains. These devices can be accessed by any operating
556           system that implements a compatible front end.
557
558           The corresponding Linux frontend driver is enabled by the
559           CONFIG_XEN_NETDEV_FRONTEND configuration option.
560
561           The backend driver presents a standard network device
562           endpoint for each paravirtual network device to the driver
563           domain network stack. These can then be bridged or routed
564           etc in order to provide full network connectivity.
565
566           If you are compiling a kernel to run in a Xen network driver
567           domain (often this is domain 0) you should say Y here. To
568           compile this driver as a module, chose M here: the module
569           will be called xen-netback.
570
571 config VMXNET3
572         tristate "VMware VMXNET3 ethernet driver"
573         depends on PCI && INET
574         depends on PAGE_SIZE_LESS_THAN_64KB
575         help
576           This driver supports VMware's vmxnet3 virtual ethernet NIC.
577           To compile this driver as a module, choose M here: the
578           module will be called vmxnet3.
579
580 config FUJITSU_ES
581         tristate "FUJITSU Extended Socket Network Device driver"
582         depends on ACPI
583         help
584           This driver provides support for Extended Socket network device
585           on Extended Partitioning of FUJITSU PRIMEQUEST 2000 E2 series.
586
587 source "drivers/net/thunderbolt/Kconfig"
588 source "drivers/net/hyperv/Kconfig"
589
590 config NETDEVSIM
591         tristate "Simulated networking device"
592         depends on DEBUG_FS
593         depends on INET
594         depends on IPV6 || IPV6=n
595         depends on PSAMPLE || PSAMPLE=n
596         select NET_DEVLINK
597         help
598           This driver is a developer testing tool and software model that can
599           be used to test various control path networking APIs, especially
600           HW-offload related.
601
602           To compile this driver as a module, choose M here: the module
603           will be called netdevsim.
604
605 config NET_FAILOVER
606         tristate "Failover driver"
607         select FAILOVER
608         help
609           This provides an automated failover mechanism via APIs to create
610           and destroy a failover master netdev and manages a primary and
611           standby slave netdevs that get registered via the generic failover
612           infrastructure. This can be used by paravirtual drivers to enable
613           an alternate low latency datapath. It also enables live migration of
614           a VM with direct attached VF by failing over to the paravirtual
615           datapath when the VF is unplugged.
616
617 config NETDEV_LEGACY_INIT
618         bool
619         depends on ISA
620         help
621           Drivers that call netdev_boot_setup_check() should select this
622           symbol, everything else no longer needs it.
623
624 endif # NETDEVICES