Add the hptrr(4) driver for HighPoint RocketRAID 17xx, 22xx, 23xx and 25xx.
[dragonfly.git] / share / man / man4 / bce.4
1 .\" Copyright (c) 2006 Broadcom Corporation
2 .\"  David Christensen <davidch@broadcom.com>.  All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\"
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. Redistributions in binary form must reproduce the above copyright
11 .\"    notice, this list of conditions and the following disclaimer in the
12 .\"    documentation and/or other materials provided with the distribution.
13 .\" 3. Neither the name of Broadcom Corporation nor the name of its contributors
14 .\"    may be used to endorse or promote products derived from this software
15 .\"    without specific prior written consent.
16 .\"
17 .\" THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS'
18 .\" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
19 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
20 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS
21 .\" BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
22 .\" CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
23 .\" SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
24 .\" INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
25 .\" CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
26 .\" ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF
27 .\" THE POSSIBILITY OF SUCH DAMAGE.
28 .\"
29 .\" $FreeBSD: src/share/man/man4/bce.4,v 1.7 2007/02/09 18:26:13 brueffer Exp $
30 .\"
31 .Dd April 7, 2012
32 .Dt BCE 4
33 .Os
34 .Sh NAME
35 .Nm bce
36 .Nd "Broadcom NetXtreme II (BCM5706/BCM5708) PCI/PCIe Gigabit Ethernet adapter driver"
37 .Sh SYNOPSIS
38 To compile this driver into the kernel,
39 place the following lines in your
40 kernel configuration file:
41 .Bd -ragged -offset indent
42 .Cd "device miibus"
43 .Cd "device bce"
44 .Ed
45 .Pp
46 Alternatively, to load the driver as a
47 module at boot time, place the following line in
48 .Xr loader.conf 5 :
49 .Bd -literal -offset indent
50 if_bce_load="YES"
51 .Ed
52 .Sh DESCRIPTION
53 The
54 .Nm
55 driver supports Broadcom's NetXtreme II product family, including the
56 BCM5706 and BCM5708 Ethernet controllers.
57 .Pp
58 The NetXtreme II product family is composed of various Converged NIC (or CNIC)
59 Ethernet controllers which support a TCP Offload Engine (TOE), Remote DMA (RDMA),
60 and iSCSI acceleration, in addition to standard L2 Ethernet traffic, all on the
61 same controller.
62 The following features are supported in the
63 .Nm
64 driver under
65 .Dx :
66 .Pp
67 .Bl -item -offset indent -compact
68 .It
69 .\"IP/TCP/UDP checksum offload
70 TCP/UDP checksum offload
71 .\".It
72 .\"Jumbo frames (up to 9022 bytes)
73 .It
74 VLAN tag stripping
75 .It
76 Interrupt coalescing
77 .It
78 10/100/1000Mbps operation in full-duplex mode
79 .It
80 10/100Mbps operation in half-duplex mode
81 .El
82 .Pp
83 The
84 .Nm
85 driver supports the following media types:
86 .Bl -tag -width ".Cm 10baseT/UTP"
87 .It Cm autoselect
88 Enable autoselection of the media type and options.
89 The user can manually override
90 the autoselected mode by adding media options to
91 .Xr rc.conf 5 .
92 .It Cm 10baseT/UTP
93 Set 10Mbps operation.
94 The
95 .Xr ifconfig 8
96 .Cm mediaopt
97 option can also be used to select either
98 .Cm full-duplex
99 or
100 .Cm half-duplex
101 modes.
102 .It Cm 100baseTX
103 Set 100Mbps (Fast Ethernet) operation.
104 The
105 .Xr ifconfig 8
106 .Cm mediaopt
107 option can also be used to select either
108 .Cm full-duplex
109 or
110 .Cm half-duplex
111 modes.
112 .It Cm 1000baseT
113 Set 1000baseT operation over twisted pair.
114 Only
115 .Cm full-duplex
116 mode is supported.
117 .El
118 .Pp
119 The
120 .Nm
121 driver supports the following media options:
122 .Bl -tag -width ".Cm full-duplex"
123 .It Cm full-duplex
124 Force full duplex operation.
125 .It Cm half-duplex
126 Force half duplex operation.
127 .El
128 .Pp
129 For more information on configuring this device, see
130 .Xr ifconfig 8 .
131 The
132 .Nm
133 driver supports
134 .Xr polling 4 .
135 .Sh TUNABLES
136 .Bl -tag -width ".Va hw.bce.tx_ticks_int"
137 .It Va hw.bce.tx_bds
138 Maximum number of sending BDs which must be processed by the device
139 before the device updates the status block and generates interrupt.
140 It is used together with
141 .Va hw.bce.tx_ticks
142 to achieve TX interrupt moderation.
143 Default value is 24.
144 .It Va hw.bce.tx_bds_int
145 Maximum number of sending BDs which must be processed by the device
146 before the device updates the status block
147 during host interrupt processing.
148 Default value is 20.
149 .It Va hw.bce.tx_ticks
150 How often status block should be updated and interrupt should be generated
151 by the device,
152 due to sending packets.
153 It is used together with
154 .Va hw.bce.tx_bds
155 to achieve TX interrupt moderation.
156 Default value is 1000 (microseconds).
157 .It Va hw.bce.tx_ticks_int
158 How often status block should be updated by the device
159 during host interrupt processing,
160 due to sending packets.
161 Default value is 80 (microseconds).
162 .It Va hw.bce.rx_bds
163 Maximum number of BDs which must be received by the device
164 before the device updates the status block and generates interrupt.
165 It is used together with
166 .Va hw.bce.rx_ticks
167 to achieve RX interrupt moderation.
168 Default value is 24.
169 .It Va hw.bce.rx_bds_int
170 Maximum number of BDs which must be received by the device
171 before the device updates the status block
172 during host interrupt processing.
173 Default value is 6.
174 .It Va hw.bce.rx_ticks
175 How often status block should be updated and interrupt should be generated
176 by the device,
177 due to receiving packets.
178 It is used together with
179 .Va hw.bce.rx_bds
180 to achieve RX interrupt moderation.
181 Default value is 100 (microseconds).
182 .It Va hw.bce.rx_ticks_int
183 How often status block should be updated by the device
184 during host interrupt processing,
185 due to receiving packets.
186 Default value is 18 (microseconds).
187 .It Va hw.bce.msi.enable
188 By default, the driver will use MSI if it is supported.
189 This behavior can be turned off by setting this tunable to 0.
190 .El
191 .Sh HARDWARE
192 The
193 .Nm
194 driver provides support for various NICs based on the Broadcom NetXtreme II
195 family of Gigabit Ethernet controllers, including the
196 following:
197 .Pp
198 .Bl -bullet -compact
199 .It
200 HP NC370T Multifunction Gigabit Server Adapter
201 .It
202 HP NC370i Multifunction Gigabit Server Adapter
203 .El
204 .Sh DIAGNOSTICS
205 .Bl -diag
206 .It "bce%d: PCI memory allocation failed!"
207 The driver has encountered a fatal initialization error.
208 .It "bce%d: PCI map interrupt failed!"
209 The driver has encountered a fatal initialization error.
210 .It "bce%d: Unsupported controller revision (%c%d)"
211 The driver does not support the controller revision in use.
212 .It "bce%d: Controller initialization failed!"
213 The driver has encountered a fatal initialization error.
214 .It "bce%d: NVRAM test failed!"
215 The driver could not access the controller NVRAM correctly.
216 .It "bce%d: DMA resource allocation failed!"
217 The driver could not allocate DMA memory to setup the controllers
218 host memory data structures.
219 .It "bce%d: Interface allocation failed!"
220 The driver could not create a network interface for the controller.
221 .It "bce%d: PHY probe failed!"
222 The driver could not access the PHY used by the controller.
223 .It "bce%d: Failed to setup IRQ!"
224 The driver could not initialize the IRQ handler.
225 .It "bce%d: Error: PHY read timeout!"
226 The driver could not read a PHY register before the timeout period expired.
227 .It "bce%d: PHY write timeout!"
228 The driver could not write to the PHY register because a timeout occurred.
229 .It "bce%d: Timeout error reading NVRAM at offset 0x%08X!"
230 The driver could not write to NVRAM because a timeout occurred.
231 .It "bce%d: Unknown Flash NVRAM found!"
232 The driver does not recognize the NVRAM device being used and therefore
233 cannot access it correctly.
234 .It "bce%d: Invalid NVRAM magic value!"
235 The driver cannot read NVRAM or the NVRAM is corrupt.
236 .It "bce%d: Invalid Manufacturing Information NVRAM CRC!"
237 The driver cannot read NVRAM or the NVRAM is corrupt.
238 .It "bce%d: Invalid Feature Configuration Information NVRAM CRC!"
239 The driver cannot read NVRAM or the NVRAM is corrupt.
240 .It "bce%d: DMA mapping error!"
241 The driver was unable to map memory into DMA addressable space required
242 by the controller.
243 .It "bce%d: Could not allocate parent DMA tag!"
244 The driver could not allocate a PCI compatible DMA tag.
245 .It "bce%d: Could not allocate status block DMA tag!"
246 The driver could not allocate a DMA tag for the controller's
247 status block.
248 .It "bce%d: Could not allocate status block DMA memory!"
249 The driver could not allocate DMA addressable memory for the controller's
250 status block.
251 .It "bce_d: Could not map status block DMA memory!"
252 The driver could not map the status block memory into the controller's DMA
253 address space.
254 .It "bce%d: Could not allocate statistics block DMA tag!"
255 The driver could not allocate a DMA tag for the controller's
256 statistics block.
257 .It "bce%d: Could not allocate statistics block DMA memory!"
258 The driver could not allocate DMA addressable memory for the controller's
259 statistics block.
260 .It "bce%d: Could not map statistics block DMA memory!"
261 The driver could not map the statistics block memory into the controller's DMA
262 address space.
263 .It "bce%d: Could not allocate TX descriptor chain DMA tag!"
264 The driver could not allocate a DMA tag for the controller's
265 TX chain.
266 .It "bce%d: Could not allocate TX descriptor chain DMA memory!"
267 The driver could not allocate DMA addressable memory for the controller's
268 TX chain.
269 .It "bce%d: Could not map TX descriptor chain DMA memory!"
270 The driver could not map the TX descriptor chain memory into the controller's DMA
271 address space.
272 .It "bce%d: Could not allocate TX mbuf DMA tag!"
273 The driver could not allocate a DMA tag for the controller's
274 TX mbuf memory.
275 .It "bce%d: Unable to create TX mbuf DMA map!"
276 The driver could not map the TX mbuf memory into the controller's DMA
277 address space.
278 .It "bce%d: Could not allocate RX descriptor chain DMA tag!"
279 The driver could not allocate a DMA tag for the controller's
280 RX chain.
281 .It "bce%d: Could not allocate RX descriptor chain "
282 The driver could not allocate DMA addressable memory for the controller's
283 RX chain.
284 .It "bce%d: Could not map RX descriptor chain DMA memory!"
285 The driver could not map the RX descriptor chain memory into the controller's DMA
286 address space.
287 .It "bce%d: Could not allocate RX mbuf DMA tag!"
288 The driver could not allocate a DMA tag for the controller's
289 RX mbuf memory.
290 .It "bce%d: Unable to create RX mbuf DMA map!"
291 The driver could not map the RX mbuf memory into the controller's DMA
292 address space.
293 .It "bce%d: Firmware synchronization timeout!"
294 The driver was not able to synchronize with the firmware running on the
295 controller.
296 The firmware may be stopped or hung.
297 .It "bce%d: Invalid Ethernet address!"
298 The driver was not able to read a valid Ethernet MAC address from NVRAM.
299 .It "bce%d: Reset failed!"
300 The driver has encountered a fatal initialization error.
301 .It "bce%d: Byte swap is incorrect!"
302 The driver has encountered a fatal initialization error.
303 Contact the author
304 with details of the CPU architecture and system chipset in use.
305 .It "bce%d: Firmware did not complete initialization!"
306 The driver has encountered a fatal initialization error.
307 .It "bce%d: Bootcode not running!"
308 The driver has encountered a fatal initialization error.
309 .It "bce%d: Error mapping mbuf into RX chain!"
310 The driver could not map a RX mbuf into DMA addressable memory.
311 .It "bce%d: Error filling RX chain: rx_bd[0x%04X]!"
312 The driver was unable to allocate enough mbufs to fill the RX chain
313 during initialization.
314 Try increasing the number of mbufs available in
315 the system, increase system memory.
316 .\"or if using jumbo frames, make sure enough 9KB mbufs are available.
317 .It "bce%d: Failed to allocate new mbuf, incoming frame dropped!"
318 The driver was unable to allocate a new mbuf for the RX chain and reused
319 the mbuf for the received frame, dropping the incoming frame in the process.
320 Try increasing the number of mbufs available in the system or increase system
321 memory.
322 .It "bce%d: Controller reset failed!"
323 A fatal initialization error has occurred.
324 .It "bce%d: Controller initialization failed!"
325 A fatal initialization error has occurred.
326 .It "bce%d: Block initialization failed!"
327 A fatal initialization error has occurred.
328 .It "bce%d: Error mapping mbuf into TX chain!"
329 The driver could not map a TX mbuf into DMA addressable memory.
330 .It "bce%d: Watchdog timeout occurred, resetting!"
331 The device has stopped responding to the network, there is a problem
332 with the cable connection, or a driver logic problem has occurred..
333 .It "bce%d: Fatal attention detected: 0x%08X!"
334 A controller hardware failure has occurred.
335 If the problem continues replace the controller.
336 .El
337 .Sh SEE ALSO
338 .Xr altq 4 ,
339 .Xr arp 4 ,
340 .Xr ifmedia 4 ,
341 .Xr miibus 4 ,
342 .Xr netintro 4 ,
343 .Xr ng_ether 4 ,
344 .Xr polling 4 ,
345 .Xr vlan 4 ,
346 .Xr ifconfig 8
347 .Sh HISTORY
348 The
349 .Nm
350 device driver first appeared in
351 .Fx 6.1 .
352 .Sh AUTHORS
353 The
354 .Nm
355 driver was written by
356 .An David Christensen Aq davidch@broadcom.com .